Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathKKS_equipment.json
232 lines (232 loc) · 9.45 KB
/
KKS_equipment.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
{
"Type": {
"A": "Mechanical equipment",
"B": "Mechanical equipment",
"C": "Direct measuring circuits",
"D": "Closed loop control circuits",
"E": "Analog and binary signal conditioning",
"F": "Indirect measuring circuits",
"G": "Electrical",
"H": "Subassemblies of main and heavy machinery",
"J": "Nuclear assemblies"
},
"Equipment": {
"AA": "Valves, dampers, etc., incl. actuators, also manual;\nrupturedisk equipment",
"AB": "Isolating elements, air locks",
"AC": "Heat exchangers, heat transfer surfaces",
"AD": "-blocked-",
"AE": "Turning, driving, lifting and slewing gear\n(also manipulators)",
"AF": "Continuous conveyors, feeders (escalators)",
"AG": "Generator units",
"AH": "Heating, cooling and air conditioning units",
"AJ": "Size reduction equipment, only as part of process",
"AK": "Compacting and packaging equipment, only as part of process",
"AL": "-blocked-",
"AM": "Mixers, agitators",
"AN": "Compressor units, fans",
"AP": "Pump units",
"AQ": "-blocked-",
"AR": "-blocked-",
"AS": "Adjusting and tensioning equipment for non-electrical\nvariables (to be applied only, if the actuator forms itself\na constructive unit with another equipment unit)",
"AT": "Cleaning, drying, filtering and separating equipment,\nexcl. *BT*",
"AU": "Braking, gearbox, coupling equipment, non-electrical\nconverters",
"AV": "Combustion equipment",
"AW": "Stationary tooling, treatment equipment",
"AX": "Test and monitoring equipment for plant maintenance",
"AY": "-blocked-",
"AZ": "-blocked-",
"BA": "-blocked-",
"BB": "Storage equipment (tanks)",
"BC": "-blocked-",
"BD": "-blocked-",
"BE": "Shafts (for erection and maintenance only)",
"BF": "Foundations",
"BG": "-blocked-",
"BH": "-blocked-",
"BJ": "-blocked-",
"BK": "-blocked-",
"BL": "-blocked-",
"BM": "-blocked-",
"BN": "Jet pumps, ejectors, injectors",
"BP": "Flow restrictors, limiters, orifices (not metering orifices)",
"BQ": "Hangers, supports, racks, piping penetrations",
"BR": "Piping, ductwork, chutes",
"BS": "Silencers",
"BT": "Flue gas catalytic converter modules",
"BU": "Insulation, sheathing",
"BV": "-blocked-",
"BW": "-blocked-",
"BX": "-blocked-",
"BY": "-blocked-",
"BZ": "-blocked-",
"IN": "19227, part 1,\nSeptember 1973 edition, table 1, initial letter)",
"CA": "-blocked-",
"CB": "-blocked-",
"CC": "-blocked-",
"CD": "Density",
"CE": "Electrical variables (e.g. current, voltage, power,\nelectr. frequency)",
"CF": "Flow, rate",
"CG": "Distance, length, position, direction of rotation",
"CH": "Manual input as manually operated sensor\n(e.g. fire detector)",
"CJ": "-blocked-",
"CK": "Time",
"CL": "Level (also for dividing line)",
"CM": "Moisture, humidity",
"CN": "-blocked-",
"CP": "Pressure",
"CQ": "Quality variables (analysis, material properties), other\nthan *CD*, *CM*, *CV*",
"CR": "Radiation variables",
"CS": "Velocity, speed, frequency (mechanical), acceleration",
"CT": "Temperature",
"CU": "Combined and other variables",
"CV": "Viscosity",
"CW": "Weight, mass",
"CX": "Neutron flux",
"CY": "Vibration, expansion",
"CZ": "-blocked-",
"DA": "-blocked-",
"DB": "-blocked-",
"DC": "-blocked-",
"DD": "Density",
"DE": "Electrical variables (e.g. current, voltage, power,\nelectr. frequency)",
"DF": "Flow, rate",
"DG": "Distance, length, position, direction of rotation",
"DH": "-blocked-",
"DJ": "-blocked-",
"DK": "Time",
"DL": "Level (also for dividing line)",
"DM": "Moisture, humidity",
"DN": "-blocked-",
"DP": "Pressure",
"DQ": "Quality variables (analysis, material properties), other\nthan *DD*, *DM*, *DV*",
"DR": "Radiation variables",
"DS": "Velocity, speed, frequency (mechanical), acceleration",
"DT": "Temperature",
"DU": "Combined and other variables",
"DV": "Viscosity",
"DW": "Weight, mass",
"DX": "Neutron flux",
"DY": "Vibration, expansion",
"DZ": "-blocked-",
"EA": "Open loop control (free for use)",
"EB": "Open loop control (free for use)",
"EC": "Open loop control (free for use)",
"ED": "Open loop control (free for use)",
"EE": "Open loop control (free for use)",
"EF": "-blocked-",
"EG": "Alarm, annunciation (free for use)",
"EH": "Alarm, annunciation (free for use)",
"EJ": "Alarm, annunciation (free for use)",
"EK": "Alarm, annunciation (free for use)",
"EL": "-blocked-",
"EM": "Process computer (free for use)",
"EN": "Process computer (free for use)",
"EP": "Process computer (free for use)",
"EQ": "Process computer (free for use)",
"ER": "Reactor protection",
"ES": "-blocked-",
"ET": "-blocked-",
"EU": "Combined analog and binary signal conditioning",
"EV": "-blocked-",
"EW": "Protection (free for use)",
"EX": "Protection (free for use)",
"EY": "Protection (free for use)",
"EZ": "Protection (free for use)",
"FA": "-blocked-",
"FB": "-blocked-",
"FC": "-blocked-",
"FD": "Density",
"FE": "Electrical variables (e.g. electr. efficiency, power)",
"FF": "Flow, rate",
"FG": "Distance, length, position, direction of rotation",
"FH": "-blocked-",
"FJ": "-blocked-",
"FK": "Time",
"FL": "Level (also for dividing line)",
"FM": "Moisture, humidity",
"FN": "-blocked-",
"FP": "Pressure",
"FQ": "Quality variables (analysis, material properties), other\nthan *FD*, *FM*, *FV*",
"FR": "Radiation variables",
"FS": "Velocity, speed, frequency (mechanical), acceleration",
"FT": "Temperature",
"FU": "Combined and other variables",
"FV": "Viscosity",
"FW": "Weight, mass",
"FX": "Neutron flux",
"FY": "Vibration, expansion",
"FZ": "-blocked-",
"GA": "Junction boxes and cable",
"GB": "Junction boxes and cable",
"GC": "Junction boxes and cable",
"GD": "Junction boxes and cable",
"GE": "Junction boxes and cable",
"GF": "Junction boxes and cable",
"GG": "Junction boxes and cable",
"GH": "Electrical and instrumentation and control installation\nunits identified as per process system (e.g. cubicles,\nboxes)",
"GJ": "Processing and storage equipment for automation systems",
"GK": "Information display and operator control equipment for\nprocess computers and automation systems",
"GL": "Limiting equipment (i.g. short circuit current limiting\nreactor)",
"GM": "Junction boxes for light-current systems of national\ntelecommunication services",
"GN": "Network equipment",
"GP": "Subdistribution",
"GQ": "Subdistribution",
"GR": "DC generating equipment, batteries",
"GS": "Switchgear equipment if not identified under process\nequipment",
"GT": "Transformer equipment",
"GU": "Converter equipment",
"GV": "Structure-related earthing and lightning protection\nequipment, surge arrestors",
"GW": "Cabinet power supply equipment",
"GX": "Actuating equipment for electrical variables",
"GY": "Junction boxes for light-current systems (not of national\ntelecommunication services)",
"GZ": "Hangers, supports and racks for electrical and\ninstrumentation and control equipment",
"HA": "Machine stationary assembly",
"HB": "Machine rotating assembly",
"HC": "-blocked-",
"HD": "Bearing assembly",
"HE": "-blocked-",
"HF": "-blocked-",
"HG": "-blocked-",
"HH": "-blocked-",
"HJ": "-blocked-",
"HK": "-blocked-",
"HL": "-blocked-",
"HM": "-blocked-",
"HN": "-blocked-",
"HP": "-blocked-",
"HQ": "-blocked-",
"HR": "-blocked-",
"HS": "-blocked-",
"HT": "-blocked-",
"HU": "-blocked-",
"HV": "-blocked-",
"HW": "-blocked-",
"HX": "-blocked-",
"HY": "-blocked-",
"HZ": "-blocked-",
"JA": "Absorber assemblies",
"JB": "Fuel assemblies\n(also includes block-type, cluster-type and spherical fuel\nelements)",
"JC": "Breeder assemblies",
"JD": "Flow restrictors (assemblies)",
"JE": "Burnable absorber assemblies",
"JF": "Reflector assemblies",
"JG": "Plenum assemblies",
"JH": "-blocked-",
"JJ": "-blocked-",
"JK": "-blocked-",
"JL": "-blocked-",
"JM": "Moderator assemblies",
"JN": "Neutron sources",
"JP": "-blocked-",
"JQ": "-blocked-",
"JR": "-blocked-",
"JS": "Shielding equipment",
"JT": "-blocked-",
"JU": "-blocked-",
"JV": "-blocked-",
"JW": "-blocked-",
"JX": "-blocked-",
"JY": "-blocked-",
"JZ": "Special assemblies"
}
}