Skip to content

Improve Resilience Error Messaging when Infeasible #488

Open
@hdunham

Description

@hdunham

Steps to reproduce:

ERP site
Resilience, PV, Grid (no battery or generator)
any location and utility rate and building
outage of 48 hours (so it includes nighttime when there is no PV energy - making it impossible to meet load without battery or generator)

Expected:

Infeasible Error message:
"Oops! Please check the errors below.
REopt could not find an optimal solution for these inputs. For resilience runs, an 'infeasible' status is likely due to system size constraints that prevent the load from being met during a grid outage. For off-grid runs, an 'infeasible' status may be due to load operating reserve, PV operating reserve, or minimum load met requirements that are infeasible with the selected technologies and system size constraints.Please adjust these inputs and try again."

Actual:

Generic Unexpected error message:
"Oops! Please check the errors below.
Unexpected Error. Please visit https://github.com/NREL/REopt-API-Analysis/discussions for support with common API usage issues. You can also email [email protected] with your run_uuid (f143199c-a151-4583-b454-199570328674) for support."