Add an end-use subcategory field to the WaterHeater:HeatPump:PumpedCondenser & WrappedCondenser objects #11559

@bonnema

Description

@bonnema

General Summary

There does not appear to be a way to specify an end-use subcategory for the WaterHeater:HeatPump:PumpedCondenser and WaterHeater:HeatPump:WrappedCondenser objects.

Detailed Description

The WaterHeater:HeatPump:PumpedCondenser and WaterHeater:HeatPump:WrappedCondenser objects require WaterHeater:Mixed and/or WaterHeater:Stratified tank objects, which have end-use fields, but these fields are only populated if the water heater tank object consumes energy (electricity, gas, etc.). When it's used as a tank only, these fields seem to be ignored. I am not sure if the same pattern exists for other required HPWH objects (like fans).

Possible Implementation

I think a solution would be either (1) add end-use subcategory fields for the WaterHeater:HeatPump:PumpedCondenser and WaterHeater:HeatPump:WrappedCondenser objects (would be an IDD change), or (2) utilize the end-use subcategory fields in the required WaterHeater:Mixed and/or WaterHeater:Stratified objects, just make sure the end-use subcategory makes its way to the parent object. Option 2 might be confusing if the same thing applies to other required HPWH objects (like fans).

Metadata

Metadata

Assignees

No one assigned

    Labels

    IDDChangeCode changes impact the IDD file (cannot be merged after IO freeze)NewFeatureIncludes code to add a new feature to EnergyPlusNotIDDChangeCode does not impact IDD (can be merged after IO freeze)TriageIssue needs to be assessed and labeled, further information on reported might be needed

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions