Database Structure and Descriptions

The updated modularized refrigeration database features three distinct templates: old, new, and advanced System. Each template includes a variety of display cases and walk-in units. This is a work in progress

Field Descriptions with Units

This dataset includes refrigerated cases (refrigeration_cases), walk-in coolers (refrigeration_walkins), compressor units (refrigeration_compressors), and building-category mappings (building_category_mapping).


Refrigeration Cases (refrigeration_cases)

Field Description Unit
case_name Unique identifier for the refrigerated case N/A
template Classification of the case as Old, New, or Advanced refrigeration system N/A
operation_type Indicates whether the case operates at Low Temperature (LT < -18°C) or Medium Temperature (MT -2°C to 4°C) N/A
rated_capacity Total full-load cooling capacity per unit length at rated conditions W/m
unit_length Physical length of an individual refrigerated case m
number_of_units Total number of refrigerated cases grouped together N/A
total_length Sum of all refrigerated case lengths in a given group m
total_capacity Full-load cooling capacity of all cases in the group per unit length under rated conditions W/m
case_operating_temperature Average internal air and product temperature within the refrigerated case during operation °C
evaporator_temperature Design evaporator coil or brine inlet temperature influencing heat exchange °C
rated_latent_heat_ratio Ratio of latent cooling capacity to total cooling capacity at rated conditions N/A
rated_runtime_fraction Expected fraction of operational runtime under rated conditions N/A
latent_case_credit_curve_type Defines curve used to adjust latent case credits at off-rated conditions N/A
latent_case_credit_curve_name Name of the cubic performance curve defining variation in latent case credit at off-rated conditions N/A
fan_power Power consumption of the case’s fans per unit length W/m
lighting_power Total lighting power required per unit length of the refrigerated case W/m
case_lighting_schedules Schedule governing when the case lighting operates N/A
fraction_of_lighting_energy_to_case Proportion of lighting energy contributing to the refrigerated case heat load N/A
anti_sweat_power Electric anti-sweat heater power per unit length of the refrigerated case W/m
anti_sweat_heater_control_type Method used to regulate the anti-sweat heaters N/A
fraction_of_anti_sweat_heater_energy_to_cases Proportion of anti-sweat heater energy directly contributing to case heat load N/A
defrost_power Electrical power used for defrosting per unit length of the refrigerated case W/m
defrost_type Method of defrosting used N/A
defrost_schedules Schedule indicating when defrost cycles occur N/A
drip_down_schedules Indicates whether additional time is needed for condensate drainage after defrost N/A
defrost_energy_correction_curve_type Type of correction curve modifying defrost energy use at off-rated conditions N/A
defrost_energy_correction_curve_name Cubic performance curve defining defrost energy variation at different conditions N/A
HVAC_return_air_fraction Fraction of HVAC return air passing beneath the refrigerated case, if applicable N/A
restocking_schedule Schedule indicating when the refrigerated case is restocked with products N/A
case_credit_fraction_schedule Schedule defining the fraction of both sensible and latent case credits applied to the zone or HVAC return air N/A
description Additional descriptive info for the case group N/A

Walk-ins (refrigeration_walkins)

Field Description Unit
walkin_name Unique identifier for the walk-in cooler N/A
template Classification of the walk-in cooler as Old, New, or Advanced refrigeration system N/A
operation_type Identifies whether the walk-in cooler operates at Low Temperature (LT < -18°C) or Medium Temperature (MT -2°C to 4°C) N/A
insulated_floor_area Total insulated floor area of the walk-in cooler
rated_capacity Total full-load cooling capacity (sensible plus latent) at rated conditions W
operating_temperature Average internal air and product temperature maintained within the walk-in cooler °C
rated_cooling_source_temperature Temperature of the cooling source for the walk-in cooler °C
rated_total_heating_power Total heating power including anti-sweat, door, and floor heaters W
rated_cooling_fan_power Power consumption of the cooling coil fan W
lighting_power Total lighting power in the walk-in cooler W
lighting_schedule Schedule governing when the walk-in lighting operates N/A
defrost_type Method of defrosting used in the walk-in cooler N/A
defrost_control_type Control mechanism for defrosting operations N/A
defrost_schedule Schedule indicating when defrost cycles occur N/A
drip_down_schedule Indicates whether additional time is needed for condensate drainage after defrost N/A
defrost_power Power consumption for defrosting W
temperature_termination_defrost_fraction_to_ice Fraction of defrost energy contributing to ice melting N/A
insulated_floor_uvalue Thermal transmittance (U-value) of the insulated floor W/m²·K
total_insulatedsurface_area_facing_zone Total insulated surface area (walls and ceilings) facing the conditioned zone
insulated_surface_uvalue_facing_zone Thermal transmittance (U-value) of insulated surfaces facing the zone W/m²·K
area_of_glass_reachin_doors_facing_zone Total area of glass reach-in doors facing the conditioned zone
reachin_door_uvalue Thermal transmittance (U-value) of reach-in doors W/m²·K
area_of_stocking_doors_facing_zone Total area of stocking doors facing the conditioned zone
height_of_stocking_doors_facing_zone Height of stocking doors facing the conditioned zone m
stocking_door_u Thermal transmittance (U-value) of stocking doors W/m²·K
stocking_door_schedule Schedule defining the fraction of time stocking doors are open N/A
stocking_door_opening_protection Type of stocking door opening protection used N/A
description Additional descriptive info for the walk-in N/A

Refrigeration Compressors (refrigeration_compressors)

Data headers, descriptions, and units for refrigeration compressor curves

Bicubic Curve Formula:

Curve Output = C1 + C2*x + C3*x² + C4*y + C5*y² + C6*x*y + C7*x³ + C8*y³ + C9*x²*y + C10*x*y²
  • x: Saturation temperature corresponding to suction pressure (°C), equal to evaporating temperature (°C) - 1.

  • y: Saturation temperature corresponding to discharge pressure (°C), equal to condensing temperature (°C) + 0.5.

    (Reference: Engineering Reference, EnergyPlus Version 22.2.0, Chapter 18.2.6.2 – Compressor Energy Use.)

  • C1 to C10: Coefficients used in the bicubic equation. (e.g.,coefficient1 to coefficient10)

Field Description Unit
curve_name Name of the refrigeration compressor curve N/A
template Classification of the compressor curve as Old, New, or Advanced refrigeration system N/A
operation_type Classification based on temperature operation (LT < -18°C, MT -2°C to 4°C) N/A
curve_type Specifies whether the curve defines compressor power consumption or cooling capacity N/A
coefficient1 First coefficient in the bicubic equation N/A
coefficient2 Second coefficient in the bicubic equation N/A
coefficient3 Third coefficient in the bicubic equation N/A
coefficient4 Fourth coefficient in the bicubic equation N/A
coefficient5 Fifth coefficient in the bicubic equation N/A
coefficient6 Sixth coefficient in the bicubic equation N/A
coefficient7 Seventh coefficient in the bicubic equation N/A
coefficient8 Eighth coefficient in the bicubic equation N/A
coefficient9 Ninth coefficient in the bicubic equation N/A
coefficient10 Tenth coefficient in the bicubic equation N/A
min_val_x Minimum value for the x variable (suction pressure temperature) °C
max_val_x Maximum value for the x variable (suction pressure temperature) °C
min_val_y Minimum value for the y variable (discharge pressure temperature) °C
max_val_y Maximum value for the y variable (discharge pressure temperature) °C

Building Category Mapping (building_category_mapping)

Field Description Unit
building_type Building type (e.g., SuperMarket, Convenience Store) N/A
system_type System name (e.g., case, walkin) N/A
template Template classification (old, new, advanced) N/A
base_name Case/walk-in reference name N/A
category Category for use (e.g., Deli, Ice Cream, Bloom Box) N/A
number_of_units Number of units for the given category count
description Optional notes for mapping N/A

License

This is a work in progress
Will be distributed under the terms of the BSD-3-Clause license