The updated modularized refrigeration database features three distinct templates: old, new, and advanced System. Each template includes a variety of display cases and walk-in units. This is a work in progress
This dataset includes refrigerated cases (refrigeration_cases), walk-in coolers (refrigeration_walkins), compressor units (refrigeration_compressors), and building-category mappings (building_category_mapping).
| Field | Description | Unit |
|---|---|---|
case_name |
Unique identifier for the refrigerated case | N/A |
template |
Classification of the case as Old, New, or Advanced refrigeration system | N/A |
operation_type |
Indicates whether the case operates at Low Temperature (LT < -18°C) or Medium Temperature (MT -2°C to 4°C) | N/A |
rated_capacity |
Total full-load cooling capacity per unit length at rated conditions | W/m |
unit_length |
Physical length of an individual refrigerated case | m |
number_of_units |
Total number of refrigerated cases grouped together | N/A |
total_length |
Sum of all refrigerated case lengths in a given group | m |
total_capacity |
Full-load cooling capacity of all cases in the group per unit length under rated conditions | W/m |
case_operating_temperature |
Average internal air and product temperature within the refrigerated case during operation | °C |
evaporator_temperature |
Design evaporator coil or brine inlet temperature influencing heat exchange | °C |
rated_latent_heat_ratio |
Ratio of latent cooling capacity to total cooling capacity at rated conditions | N/A |
rated_runtime_fraction |
Expected fraction of operational runtime under rated conditions | N/A |
latent_case_credit_curve_type |
Defines curve used to adjust latent case credits at off-rated conditions | N/A |
latent_case_credit_curve_name |
Name of the cubic performance curve defining variation in latent case credit at off-rated conditions | N/A |
fan_power |
Power consumption of the case’s fans per unit length | W/m |
lighting_power |
Total lighting power required per unit length of the refrigerated case | W/m |
case_lighting_schedules |
Schedule governing when the case lighting operates | N/A |
fraction_of_lighting_energy_to_case |
Proportion of lighting energy contributing to the refrigerated case heat load | N/A |
anti_sweat_power |
Electric anti-sweat heater power per unit length of the refrigerated case | W/m |
anti_sweat_heater_control_type |
Method used to regulate the anti-sweat heaters | N/A |
fraction_of_anti_sweat_heater_energy_to_cases |
Proportion of anti-sweat heater energy directly contributing to case heat load | N/A |
defrost_power |
Electrical power used for defrosting per unit length of the refrigerated case | W/m |
defrost_type |
Method of defrosting used | N/A |
defrost_schedules |
Schedule indicating when defrost cycles occur | N/A |
drip_down_schedules |
Indicates whether additional time is needed for condensate drainage after defrost | N/A |
defrost_energy_correction_curve_type |
Type of correction curve modifying defrost energy use at off-rated conditions | N/A |
defrost_energy_correction_curve_name |
Cubic performance curve defining defrost energy variation at different conditions | N/A |
HVAC_return_air_fraction |
Fraction of HVAC return air passing beneath the refrigerated case, if applicable | N/A |
restocking_schedule |
Schedule indicating when the refrigerated case is restocked with products | N/A |
case_credit_fraction_schedule |
Schedule defining the fraction of both sensible and latent case credits applied to the zone or HVAC return air | N/A |
description |
Additional descriptive info for the case group | N/A |
| Field | Description | Unit |
|---|---|---|
walkin_name |
Unique identifier for the walk-in cooler | N/A |
template |
Classification of the walk-in cooler as Old, New, or Advanced refrigeration system | N/A |
operation_type |
Identifies whether the walk-in cooler operates at Low Temperature (LT < -18°C) or Medium Temperature (MT -2°C to 4°C) | N/A |
insulated_floor_area |
Total insulated floor area of the walk-in cooler | m² |
rated_capacity |
Total full-load cooling capacity (sensible plus latent) at rated conditions | W |
operating_temperature |
Average internal air and product temperature maintained within the walk-in cooler | °C |
rated_cooling_source_temperature |
Temperature of the cooling source for the walk-in cooler | °C |
rated_total_heating_power |
Total heating power including anti-sweat, door, and floor heaters | W |
rated_cooling_fan_power |
Power consumption of the cooling coil fan | W |
lighting_power |
Total lighting power in the walk-in cooler | W |
lighting_schedule |
Schedule governing when the walk-in lighting operates | N/A |
defrost_type |
Method of defrosting used in the walk-in cooler | N/A |
defrost_control_type |
Control mechanism for defrosting operations | N/A |
defrost_schedule |
Schedule indicating when defrost cycles occur | N/A |
drip_down_schedule |
Indicates whether additional time is needed for condensate drainage after defrost | N/A |
defrost_power |
Power consumption for defrosting | W |
temperature_termination_defrost_fraction_to_ice |
Fraction of defrost energy contributing to ice melting | N/A |
insulated_floor_uvalue |
Thermal transmittance (U-value) of the insulated floor | W/m²·K |
total_insulatedsurface_area_facing_zone |
Total insulated surface area (walls and ceilings) facing the conditioned zone | m² |
insulated_surface_uvalue_facing_zone |
Thermal transmittance (U-value) of insulated surfaces facing the zone | W/m²·K |
area_of_glass_reachin_doors_facing_zone |
Total area of glass reach-in doors facing the conditioned zone | m² |
reachin_door_uvalue |
Thermal transmittance (U-value) of reach-in doors | W/m²·K |
area_of_stocking_doors_facing_zone |
Total area of stocking doors facing the conditioned zone | m² |
height_of_stocking_doors_facing_zone |
Height of stocking doors facing the conditioned zone | m |
stocking_door_u |
Thermal transmittance (U-value) of stocking doors | W/m²·K |
stocking_door_schedule |
Schedule defining the fraction of time stocking doors are open | N/A |
stocking_door_opening_protection |
Type of stocking door opening protection used | N/A |
description |
Additional descriptive info for the walk-in | N/A |
Data headers, descriptions, and units for refrigeration compressor curves
Curve Output = C1 + C2*x + C3*x² + C4*y + C5*y² + C6*x*y + C7*x³ + C8*y³ + C9*x²*y + C10*x*y²
-
x: Saturation temperature corresponding to suction pressure (°C), equal to evaporating temperature (°C) - 1. -
y: Saturation temperature corresponding to discharge pressure (°C), equal to condensing temperature (°C) + 0.5.(Reference: Engineering Reference, EnergyPlus Version 22.2.0, Chapter 18.2.6.2 – Compressor Energy Use.)
-
C1toC10: Coefficients used in the bicubic equation. (e.g.,coefficient1tocoefficient10)
| Field | Description | Unit |
|---|---|---|
curve_name |
Name of the refrigeration compressor curve | N/A |
template |
Classification of the compressor curve as Old, New, or Advanced refrigeration system | N/A |
operation_type |
Classification based on temperature operation (LT < -18°C, MT -2°C to 4°C) | N/A |
curve_type |
Specifies whether the curve defines compressor power consumption or cooling capacity | N/A |
coefficient1 |
First coefficient in the bicubic equation | N/A |
coefficient2 |
Second coefficient in the bicubic equation | N/A |
coefficient3 |
Third coefficient in the bicubic equation | N/A |
coefficient4 |
Fourth coefficient in the bicubic equation | N/A |
coefficient5 |
Fifth coefficient in the bicubic equation | N/A |
coefficient6 |
Sixth coefficient in the bicubic equation | N/A |
coefficient7 |
Seventh coefficient in the bicubic equation | N/A |
coefficient8 |
Eighth coefficient in the bicubic equation | N/A |
coefficient9 |
Ninth coefficient in the bicubic equation | N/A |
coefficient10 |
Tenth coefficient in the bicubic equation | N/A |
min_val_x |
Minimum value for the x variable (suction pressure temperature) | °C |
max_val_x |
Maximum value for the x variable (suction pressure temperature) | °C |
min_val_y |
Minimum value for the y variable (discharge pressure temperature) | °C |
max_val_y |
Maximum value for the y variable (discharge pressure temperature) | °C |
| Field | Description | Unit |
|---|---|---|
building_type |
Building type (e.g., SuperMarket, Convenience Store) | N/A |
system_type |
System name (e.g., case, walkin) | N/A |
template |
Template classification (old, new, advanced) | N/A |
base_name |
Case/walk-in reference name | N/A |
category |
Category for use (e.g., Deli, Ice Cream, Bloom Box) | N/A |
number_of_units |
Number of units for the given category | count |
description |
Optional notes for mapping | N/A |
This is a work in progress
Will be distributed under the terms of the BSD-3-Clause license