I was thinking about the operation of the sensor and as long as it comes to measuring the filament in optimal conditions the system is valid but ... when measuring the filament while printing, a few millimeters of filament will be read 3 times. these multiple reads occur when there are retractions in the gcode. How can we compensate for this error which will be directly proportional to the number and length of the retractions?

What's your feature?

Compensation of the error due to the multiple reading of the retraction filament