@AlenHodnik
Copy link

Can't get past the username/password stage. Is Tigo/$olar always the right user/pass or can be smth else? Does installer of the inverter maybe set this?

@mletenay
Copy link
Owner

Not sure, but don't expect so.
I followed the steps from one of the links and it worked in my setup flawlessly.
Just check those linked threads, I believe there is mentioned a way how to remove authentication completely from ssh console.
AFAIR, removing stuff after A: in httpd.conf ? Something like that.

@AlenHodnik
Copy link
Author

Yes. Tried to, but seems passwords in my case dont work. Oh well.

@chicagoandy
Copy link

If you're getting the 'Done' screen after calling cgi-bin/shell, then you should be able to SSH in using the local IP.

I would double-check the basics like IP address, firewall, network connectivity.

Also doublecheck that you're using this CCA: https://www.tigoenergy.com/product/cloud-connect-advanced

@mletenay
Copy link
Owner

See the post here - https://diysolarforum.com/threads/getting-data-directly-from-a-tigo-tap-is-it-possible.37414/post-1133295
You may have older fw where the user:tigo1 credentials are used and old ssh cipher may need to be enabled.

@proggaras
Copy link

With the last firmware (3.7.7) it seems Tigo changed something. Probably there is already a solution, but they guys don't want to publish it yet: https://www.photovoltaikforum.com/thread/149592-details-protokolle-zugang-auf-tigo-cca/?postID=3829812#post3829812

@ther3zz
Copy link

ther3zz commented Jul 19, 2024

With the last firmware (3.7.7) it seems Tigo changed something. Probably there is already a solution, but they guys don't want to publish it yet: https://www.photovoltaikforum.com/thread/149592-details-protokolle-zugang-auf-tigo-cca/?postID=3829812#post3829812

I just got my system up and running, hopefully the root method is shared soon!