Class=542 (0x021E) - Class2 Level I Control

CLASS2.LEVEL1.CONTROL

Description

This class mirrors the CLASS1.CONTROL class but use a different data format with a GUID stored in the first 16 bytes of the data followed by the standard data thus offset with 16-bytes.

See CLASS2.PROTOCOL1 for more information on the data format.

Type=0 (0x00) - General event {#type0}

VSCP_TYPE_CONTROL_GENERALGeneral Event.

Type=1 (0x01) - Mute on/off {#type1}

VSCP_TYPE_CONTROL_MUTEMute/Un-mute all sound generating nodes in a zone 
Data byte Description
0 If equal to zero no mute else mute.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=2 (0x02) - (All) Lamp(s) on/off {#type2}

VSCP_TYPE_CONTROL_ALL_LAMPSTurn on/off lamps on nodes in zone.
Data byte Description
0 If equal to zero off else on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

See also CLASS1.CONTROL, Type=40 and CLASS1.CONTROL, Type=42 which don't use byte 0 but instead are separated in two distinct events.


Type=3 (0x03) - Open {#type3}

VSCP_TYPE_CONTROL_OPENPerform open on all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=4 (0x04) - Close {#type4}

VSCP_TYPE_CONTROL_CLOSEPerform close on all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=5 (0x05) - TurnOn {#type5}

VSCP_TYPE_CONTROL_TURNONTurn On a nodes in a zone/subzone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=6 (0x06) - TurnOff {#type6}

VSCP_TYPE_CONTROL_TURNOFFTurn Off a nodes in a zone/subzone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=7 (0x07) - Start {#type7}

VSCP_TYPE_CONTROL_STARTStart all nodes in a zone.
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=8 (0x08) - Stop {#type8}

VSCP_TYPE_CONTROL_STOPStop all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=9 (0x09) - Reset {#type9}

VSCP_TYPE_CONTROL_RESETPerform Reset on all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=10 (0x0A) - Interrupt {#type10}

VSCP_TYPE_CONTROL_INTERRUPTPerform Interrupt on all nodes in zone. 
Data byte Description
0 Interrupt level. (0 – 255 , zero is lowest interrupt level. ).
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=11 (0x0B) - Sleep {#type11}

VSCP_TYPE_CONTROL_SLEEPPerform Sleep on all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=12 (0x0C) - Wakeup {#type12}

VSCP_TYPE_CONTROL_WAKEUPWakeup all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=13 (0x0D) - Resume {#type13}

VSCP_TYPE_CONTROL_RESUMEResume all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=14 (0x0E) - Pause {#type14}

VSCP_TYPE_CONTROL_PAUSEPause all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=15 (0x0F) - Activate {#type15}

VSCP_TYPE_CONTROL_ACTIVATEActivate all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=16 (0x10) - Deactivate {#type16}

VSCP_TYPE_CONTROL_DEACTIVATEDeactivate all nodes in zone. 
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=17 (0x11) - Reserved for future use {#type17}

VSCP_TYPE_CONTROL_RESERVED17Reserved. 

Type=18 (0x12) - Reserved for future use {#type18}

VSCP_TYPE_CONTROL_RESERVED18Reserved. 

Type=19 (0x13) - Reserved for future use {#type19}

VSCP_TYPE_CONTROL_RESERVED19Reserved.

Type=20 (0x14) - Dim lamp(s) {#type20}

VSCP_TYPE_CONTROL_DIM_LAMPSDim all dimmer devices on a segment to a specified dim value. 
Data byte Description
0 Value (0 – 100) . 0 = off, 100 = full on. 254 dim down one step. 255 dim up one step.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=21 (0x15) - Change Channel {#type21}

VSCP_TYPE_CONTROL_CHANGE_CHANNELThis is typical for changing TV channels or for changing AV amp input source etc. 
Data byte Description
0 A value between 0 and 127 indicates the channel number. A value between 128 to 157 is change down by the specified number of channels. A value between 160 to 191 is change up by the specified number of channels. A value of 255 means that this is an extended change channel event and that the channel number is sent in byte 3 and after if needed.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=22 (0x16) - Change Level {#type22}

VSCP_TYPE_CONTROL_CHANGE_LEVELChange an absolute level. 
Data byte Description
0 Absolute level.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=23 (0x17) - Relative Change Level {#type23}

VSCP_TYPE_CONTROL_RELATIVE_CHANGE_LEVEL

Relative Change Level request

Data byte Description
0 Relative level.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=24 (0x18) - Measurement Request {#type24}

VSCP_TYPE_CONTROL_MEASUREMENT_REQUESTMeasurement Request
Data byte Description
0 Zero indicates all measurements supported by node should be sent (as separate events). Non-zero indicates a node specific index specifying which measurement to send.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=25 (0x19) - Stream Data {#type25}

VSCP_TYPE_CONTROL_STREAM_DATARequest to stream data
Data byte Description
0 Sequence number which is increase by one for each stream data event sent.
1-7 Stream data.

Use this event for streamed data out from a node. The source is then given by the nickname. If a specific received is needed use Zoned Stream.


Type=26 (0x1A) - Sync {#type26}

VSCP_TYPE_CONTROL_SYNCSynchronize events on a segment. 
Data byte Description
0 Sensor index for a sensor within a module (see data coding. 255 is all sensors.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

The sensor index can be used to index units within a module also or used as some other indexing schema.


Type=27 (0x1B) - Zoned Stream Data {#type27}

VSCP_TYPE_CONTROL_ZONED_STREAM_DATARequest streamed data from nodes identified by zone/subzone.
Data byte Description
0 Sequence number which is increase by one for each stream data event sent.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3-7 Stream data.

Type=28 (0x1C) - Set Pre-set {#type28}

VSCP_TYPE_CONTROL_SET_PRESETSome nodes may have pre-set configurations to choose from. With this event a pre-set can be set for a zone/sub-zone.

A node that receive and act on this event send CLASS1.INFORMATION,

Type=48 as a response event.

Data byte Description
0 Code for pre-set to set.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=29 (0x1D) - Toggle state {#type29}

VSCP_TYPE_CONTROL_TOGGLE_STATEToggle the state of a node.

Note: This may be a bad design option as it often demands that the state should be known for the node on beforehand.

Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=30 (0x1E) - Timed pulse on {#type30}

VSCP_TYPE_CONTROL_TIMED_PULSE_ONWith this event it is possible to generate a timed pulse that is on for a specified time.
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3 Control byte.
4-7 Set time as a long with MSB in the first byte.
Control Byte

The control byte have the following bits defined

Bit Description
0-3 Time code (see table below)
4 Reserved
5 Reserved
6 Send on event ( Class=20 Type = 3 (0x03) On ) when pulse goes on.
7 Send off event ( Class=20 Type = 4 (0x04) Off ) when pulse goes off.
Time code
Code Description
0 Time specified in microseconds.
1 Time specified in milliseconds.
2 Time specified in seconds.
3 Time specified in minutes.
4 Time specified in hours.
5 Time specified in days.

Type=31 (0x1F) - Timed pulse off {#type31}

VSCP_TYPE_CONTROL_TIMED_PULSE_OFFWith this event it is possible to generate a timed pulse that is off for a specified time.
Data byte Description
0 Optional byte that have a meaning given by the issuer of the event.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3 Control byte.
4-7 Set time as a long with MSB in the first byte.
Control Byte

The control byte have the following bits defined

Bit Description
0-3 Time code (see table below)
4 Reserved
5 Reserved
6 Send on event ( Class=20 Type = 3 (0x03) On ) when pulse goes on.
7 Send off event ( Class=20 Type = 4 (0x04) Off ) when pulse goes off.
Time code
Code Description
0 Time specified in microseconds.
1 Time specified in milliseconds.
2 Time specified in seconds.
3 Time specified in minutes.
4 Time specified in hours.
5 Time specified in days.

Type=32 (0x20) - Set country/language {#type32}

VSCP_TYPE_CONTROL_SET_COUNTRY_LANGUAGESet country and language.
Data byte Description
0 Country/Language code.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3-7 Country/Language code specific
Language code Description Example
0 Custom coded system Byte 3 = 0 English, Byte 3 = 1 German or similar.
1 ISO 639-1 nl for Dutch, en for English.
2 ISO 639-2/T nid for Dutch, eng for English.
3 ISO 639-2/B dut for Dutch, eng for English.
4 ISO 639-3 nid for Dutch, eng for English.
5 IETF (RFC-5646/4647) en-US for American English. en-GB British.

ISO codes can be found here


Type=33 (0x21) - Big Change level {#type33}

VSCP_TYPE_CONTROL_BIG_CHANGE_LEVELBig Change level can be used in situations when the one byte level of CLASS1.CONTROL, Type=22 is not enough.
Data byte Description
0 Index
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3-7 Level as signed Integer. The range can be adjusted by the user by sending the needed number of bytes 1-5.

Type=34 (0x22) - Move shutter up {#type34}

VSCP_TYPE_CONTROL_SHUTTER_UPMove shutter up.
Data byte Description
0 Index.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=35 (0x23) - Move shutter down {#type35}

VSCP_TYPE_CONTROL_SHUTTER_DOWNMove shutter down.
Data byte Description
0 Index.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=36 (0x24) - Move shutter left {#type36}

VSCP_TYPE_CONTROL_SHUTTER_LEFTMove shutter left.
Data byte Description
0 Index.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=37 (0x25) - Move shutter right {#type37}

VSCP_TYPE_CONTROL_SHUTTER_RIGHTMove shutter right.
Data byte Description
0 Index.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=38 (0x26) - Move shutter to middle position {#type38}

VSCP_TYPE_CONTROL_SHUTTER_MIDDLEMove shutter to middle position.
Data byte Description
0 Index.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=39 (0x27) - Move shutter to preset position {#type39}

VSCP_TYPE_CONTROL_SHUTTER_PRESETMove shutter to preset position.
Data byte Description
0 Index.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3 Position 0-100.

Type=40 (0x28) - (All) Lamp(s) on {#type40}

VSCP_TYPE_CONTROL_ALL_LAMPS_ONTurn on all lamps in a zone.
Data byte Description
0 Not used.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

See also CLASS1.CONTROL, Type=2


Type=41 (0x29) - (All) Lamp(s) off {#type41}

VSCP_TYPE_CONTROL_ALL_LAMPS_OFFTurn off all lamps in a zone.
Data byte Description
0 Not used.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

See also CLASS1.CONTROL, Type=2


Type=42 (0x2A) - Lock {#type42}

VSCP_TYPE_CONTROL_LOCKLock devices in a zone.
Data byte Description
0 Not used.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

Type=43 (0x2B) - Unlock {#type43}

VSCP_TYPE_CONTROL_UNLOCKUnock devices in a zone.
Data byte Description
0 Not used.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.