FUNCTION read_de1, file
OPENR, lun, file, /GET_LUN
nlines=FILE_LINES(file)
dummy=STRARR(nlines)
READF, lun, dummy
FREE_LUN, lun
;Parameters to keep track of:
;1. Flight number (fltnum)
;2. Date (date)
;3. Time (time)
;4. Longitude (lon)
;5. Latitude (lat)
;6. Time Zone (GMT/CST) (time_zone)
;7. Launch altitude (launch_alt)
;8. Surface Pressure (sfc_press)
;9. Surface temp (sfc_temp)
;10 Surface humidity (sfc_hum)
;11. Total ozone column (o3col)
;12. 100 ml flow rate time (flowrate_100ml)
;13. Lab temp for flowrate (flowrate_temp)
;14. Lab humidity for flowrate (flowrate_hum)
;15. Flowrate correction (flowrate_cor)
;16. Background current (bgcurrent)
;17. Bg current, different versions sometimes output the bg in a different field, so this is the same as 16.
search_strings=['Flight number', 'Date [GMT]', 'Time [GMT]', 'Longitude', 'Latitude' $
, 'Time stamp', 'Launch altitude', 'Surface Pressure', 'Surface temperature' $
, 'Surface humidity', 'Total ozone column', 'Time (sec) to pump 100 ml' $
, 'Lab temp. for flowrate', 'Lab humidity for flowrate', 'Dry flowrate correction' $
, 'Background current', 'Prep background'] ;background current and prep background are the same thing, but different versions of the
;retrieval program output them differently. So whichever is non-zero should be used.
data=STRARR(N_ELEMENTS(search_strings))
FOR i=0, N_ELEMENTS(search_strings)-1 DO BEGIN
string_indx=WHERE(STRPOS(dummy[*], search_strings[i]) NE -1)
IF string_indx EQ -1 THEN data[i]=!VALUES.F_NAN ELSE BEGIN
data[i]=STRMID(dummy[string_indx], 30, 15)
ENDELSE
ENDFOR
RETURN, data
END
PRO Sonde_quality_control
files=FILE_SEARCH('C:\Users\Wes Cantrell\Dropbox\Sonde Data\Huntsville\Database_rebuild\HU???\DATA\','*.de1', count=nfiles)
data=STRARR(nfiles, 17)
FOR j=0, nfiles-1 DO BEGIN
data[j,*]=read_de1(files[j])
ENDFOR
date=data[*,1]
time=data[*,2]
fr_corr=FLOAT(data[*,14])
month=STRMID(date, 3, 2)
day=STRMID(date, 0, 2)
year=STRMID(date, 6, 4)
SET_PLOT, 'PS'
DEVICE, filename='C:\Users\Wes Cantrell\Dropbox\Ozonesonde Station\Flowrate_correction\flowrate_correction_analysis.ps' $
, /color;, xoffset=.5,yoffset=.5,xsize=7.5,ysize=10 $
;,/inches,/landscape
;!p.charsize=1.2 & !p.thick=2.0 & !x.thick=2.0 & !y.thick=2.0
;!p.charthick=2.0 & !p.multi=[0,1,1]
;define color table
color_table_ps
;Flowrate correction Histogram
Histoplot, fr_corr $
, xtitle='Flowrate Correction (%)' $
;, xrange=[0,100] $
, yrange=[0,0.2] $
, /FREQUENCY $
, binsize=0.1
DEVICE, /CLOSE
stop