title Model Caching
subtitle Download models once and share across all pods in a Kubernetes cluster

Large language models can take minutes to download. Without caching, every pod downloads the full model independently, wasting bandwidth and delaying startup. Dynamo supports a simple shared-storage path and a ModelExpress path for faster weight distribution across larger clusters.

Option 1: PVC + Download Job (Recommended)

The simplest approach: create a shared PVC, run a one-time Job to download the model, then mount the PVC in your DynamoGraphDeployment.

This is the pattern used by all Dynamo recipes today.

Step 1: Create a Shared PVC

apiVersion: v1
kind: PersistentVolumeClaim
metadata:
  name: model-cache
spec:
  accessModes:
    - ReadWriteMany
  resources:
    requests:
      storage: 100Gi
`ReadWriteMany` access mode is required so multiple pods can mount the PVC simultaneously. Ensure your storage class supports RWX (e.g., NFS, CephFS, or cloud-provider shared file systems).

Step 2: Download the model

apiVersion: batch/v1
kind: Job
metadata:
  name: model-download
spec:
  template:
    spec:
      restartPolicy: Never
      containers:
        - name: downloader
          image: python:3.12-slim
          command: ["sh", "-c"]
          args:
            - |
              pip install huggingface_hub hf_transfer
              HF_HUB_ENABLE_HF_TRANSFER=1 huggingface-cli download \
                $MODEL_NAME --revision $MODEL_REVISION
          env:
            - name: MODEL_NAME
              value: "Qwen/Qwen3-0.6B"
            - name: MODEL_REVISION
              value: "main"
            - name: HF_HOME
              value: /cache/huggingface
          envFrom:
            - secretRef:
                name: hf-token-secret
          volumeMounts:
            - name: model-cache
              mountPath: /cache/huggingface
      volumes:
        - name: model-cache
          persistentVolumeClaim:
            claimName: model-cache

Find the Snapshot Path

After the Job completes, the model is stored in HuggingFace's cache layout:

hub/models--<org>--<model>/snapshots/<commit-hash>/

For example, meta-llama/Llama-3.1-70B-Instruct becomes:

hub/models--meta-llama--Llama-3.1-70B-Instruct/snapshots/9d3b8e0f71f8c1e0f9b7c2a3d4e5f6a7b8c9d0e1/

To find the exact commit hash after the download Job completes:

kubectl run find-snapshot --rm -it --image=busybox --restart=Never \
  --overrides='{
    "spec": {
      "volumes": [{"name": "c", "persistentVolumeClaim": {"claimName": "model-cache"}}],
      "containers": [{
        "name": "f", "image": "busybox",
        "command": ["find", "/c/hub", "-mindepth", "3", "-maxdepth", "3", "-type", "d"],
        "volumeMounts": [{"name": "c", "mountPath": "/c"}]
      }]
    }
  }'

Alternatively, look up the commit hash on the HuggingFace Hub model page under Files and versions.

You need this path for the pvcModelPath field in a DGDR spec (see Deployment Overview — Model Caching).

Step 3: Mount in DynamoGraphDeployment

apiVersion: nvidia.com/v1alpha1
kind: DynamoGraphDeployment
metadata:
  name: my-deployment
spec:
  pvcs:
    - create: false
      name: model-cache
  services:
    VllmWorker:
      volumeMounts:
        - name: model-cache
          mountPoint: /home/dynamo/.cache/huggingface

All VllmWorker pods that mount model-cache now read from the shared cache, avoiding per-pod worker downloads. If you also want the frontend to reuse tokenizer and config files, mount the same PVC there too.

Compilation Cache

For vLLM, you can also cache compiled artifacts (CUDA graphs, etc.) with a second PVC:

spec:
  pvcs:
    - create: false
      name: model-cache
    - create: false
      name: compilation-cache
  services:
    VllmWorker:
      volumeMounts:
        - name: model-cache
          mountPoint: /home/dynamo/.cache/huggingface
        - name: compilation-cache
          mountPoint: /home/dynamo/.cache/vllm

Option 2: ModelExpress (P2P Distribution)

ModelExpress is a model weight distribution service that integrates with engine weight loading pipelines. It can publish model weights from one worker and let later workers pull those tensors from GPU memory over NIXL/RDMA instead of repeating a full storage download.

ModelExpress can also use ModelStreamer as a loading strategy. ModelStreamer streams safetensors directly from object storage or a local filesystem path into GPU memory through the runai-model-streamer package. In that setup, the first worker can stream from storage and then publish ModelExpress metadata so later workers can use the P2P path.

Use this path when startup time or fleet-wide model rollout time matters more than the simplicity of a shared PVC.

How It Works

  1. A ModelExpress server runs in the cluster and stores metadata for available sources.
  2. Engine workers use the ModelExpress loader from an MX-enabled runtime image. For vLLM, set --load-format modelexpress. For SGLang, use a runtime image whose SGLang version includes the native backend=modelexpress loader.
  3. If a compatible source is already serving the model, a new worker pulls model tensors from that source over NIXL/RDMA.
  4. If no source is available, the worker falls back to storage. With a shared filesystem (RWX PVC, NFS, hostPath), the worker reads directly from the server's cache. Without a shared filesystem, set MODEL_EXPRESS_NO_SHARED_STORAGE=1 so the client streams files from the server over gRPC; see Streaming Without Shared Storage below. When MX_MODEL_URI is set, ModelStreamer can stream safetensors from S3, GCS, Azure Blob Storage, or a local path.
  5. Workers that use a ModelExpress server set MODEL_EXPRESS_URL in the worker pod environment.

What To Configure

Layer What to configure Notes
Runtime image Include the modelexpress Python package and, for ModelStreamer, runai-model-streamer plus the object-storage dependencies. Dynamo or the engine raises an import error if the worker uses a ModelExpress loader but the package is missing.
ModelExpress server Deploy the server with Redis or Kubernetes CRD metadata backend. See the ModelExpress deployment guide.
Dynamo platform Optionally set dynamo-operator.modelExpressURL. The operator injects MODEL_EXPRESS_URL into pods when a deployment should use one platform-level ModelExpress server.
vLLM worker Set --load-format modelexpress. The Dynamo runtime image must include the MX Python client. Until an official MX-enabled runtime ships, use an explicitly built development image.
SGLang worker Use remote_instance with backend=modelexpress. This requires an SGLang runtime version containing the native ModelExpress loader plus the MX Python client in the image.
ModelStreamer Set MX_MODEL_URI to the storage location. Supported URI forms include s3://..., gs://..., az://..., an absolute local path, or a Hugging Face model ID resolved from the local cache.

Setup

Install with Dynamo Platform:

helm install dynamo-platform dynamo-platform-${RELEASE_VERSION}.tgz \
  --namespace ${NAMESPACE} \
  --set "dynamo-operator.modelExpressURL=http://model-express-server.model-express.svc.cluster.local:8080"

You can also deploy the ModelExpress server separately with the ModelExpress deployment guide and set MODEL_EXPRESS_URL directly in the worker manifest. The examples below assume the server is reachable at http://model-express-server.model-express.svc.cluster.local:8080.

Configure workers to use ModelExpress:

services:
  VllmWorker:
    extraPodSpec:
      mainContainer:
        image: <vllm-runtime-image-with-modelexpress>
        command: ["python3", "-m", "dynamo.vllm"]
        args:
          - --model
          - meta-llama/Llama-3.1-70B-Instruct
          - --load-format
          - modelexpress
        env:
          - name: VLLM_PLUGINS
            value: modelexpress
          - name: MODEL_EXPRESS_URL
            value: http://model-express-server.model-express.svc.cluster.local:8080

When dynamo-operator.modelExpressURL is configured, the operator injects MODEL_EXPRESS_URL into component pods, so you do not need to repeat it in every worker manifest. If different workers should use different ModelExpress servers, or if you are using a ModelStreamer-only flow that does not need a server, set the relevant env vars explicitly in the DGD manifest instead.

`VLLM_PLUGINS=modelexpress` is required while vLLM discovers this loader through the plugin path. Set it in the DGD manifest when using `--load-format=modelexpress`. If a manifest enables additional vLLM plugins, include `modelexpress` in the same comma-separated value.

Streaming Without Shared Storage

If the ModelExpress server's cache is on a non-shared volume (e.g. a ReadWriteOnce PVC, a cross-namespace deployment, or any topology where worker pods cannot mount the same filesystem as the server), the default shared-storage mode fails: the server reports the model as downloaded and returns its own local path, the worker cannot read that path from inside its own pod, and the load silently falls back to a direct HuggingFace download -- defeating the point of running ModelExpress.

Set MODEL_EXPRESS_NO_SHARED_STORAGE=1 on every worker pod to switch the ModelExpress client into gRPC streaming mode. The server then sends model files to the client over the existing gRPC channel and the worker writes them to its own local cache.

services:
  VllmWorker:
    extraPodSpec:
      mainContainer:
        image: <vllm-runtime-image-with-modelexpress>
        command: ["python3", "-m", "dynamo.vllm"]
        args:
          - --model
          - meta-llama/Llama-3.1-70B-Instruct
          - --load-format
          - modelexpress
        env:
          - name: MODEL_EXPRESS_URL
            value: http://model-express-server.model-express.svc.cluster.local:8080
          - name: MODEL_EXPRESS_NO_SHARED_STORAGE
            value: "1"

No volume mount for the ModelExpress cache is required on worker pods in this mode.

Use this path when:

  • The server runs with an RWO PVC, or in a different namespace from the workers.
  • The cluster has no RDMA / InfiniBand fabric available, so P2P over NIXL is not an option.
  • You want ModelExpress to act as a centralized download-and-cache server (one HuggingFace pull, fan out over gRPC to many workers) without standing up object storage and MX_MODEL_URI.

Shared-filesystem mode is still faster when available, so prefer an RWX PVC mounted on both the server and the workers when the storage class supports it. See the ModelExpress storage access modes documentation for the full trade-off and tuning knobs (chunk size, etc.).

ModelStreamer From Object Storage

Set MX_MODEL_URI when the first worker should stream safetensors directly from storage instead of reading a PVC or relying on a prior source worker.

services:
  VllmWorker:
    extraPodSpec:
      mainContainer:
        image: <vllm-runtime-image-with-modelexpress-and-modelstreamer>
        command: ["python3", "-m", "dynamo.vllm"]
        args:
          - --model
          - meta-llama/Llama-3.1-70B-Instruct
          - --load-format
          - modelexpress
        env:
          - name: MX_MODEL_URI
            value: s3://my-model-bucket/meta-llama/Llama-3.1-70B-Instruct
          - name: RUNAI_STREAMER_CONCURRENCY
            value: "8"

ModelStreamer relies on the underlying cloud SDK credentials:

Storage backend MX_MODEL_URI example Credential options
S3 or S3-compatible storage s3://bucket/path/to/model IRSA / workload identity, AWS_ACCESS_KEY_ID, AWS_SECRET_ACCESS_KEY, AWS_SESSION_TOKEN, AWS_DEFAULT_REGION, and optional AWS_ENDPOINT_URL
Google Cloud Storage gs://bucket/path/to/model GKE Workload Identity, Application Default Credentials, or GOOGLE_APPLICATION_CREDENTIALS
Azure Blob Storage az://container/path/to/model Managed Identity, service principal env vars, or AZURE_ACCOUNT_NAME / AZURE_ACCOUNT_KEY
Local filesystem or PVC /models/meta-llama/Llama-3.1-70B-Instruct Mount the path into the worker pod

Credentials are consumed by the storage SDKs in the worker pod. They do not flow through the ModelExpress server.

Relationship To Shadow Engine Failover

ModelExpress and ModelStreamer are model loading and distribution paths. They are not required for Shadow Engine Failover, and enabling them does not create standby engines.

Use Shadow Engine Failover only when you specifically need an active/shadow recovery topology backed by GPU Memory Service (GMS), DRA, and a backend load format such as --load-format gms. Keep the ModelExpress / ModelStreamer configuration separate unless you have validated a combined workflow for your runtime image and cluster.

When to Use ModelExpress

Scenario Recommended Approach
Small cluster, simple setup PVC + Download Job
Large cluster, many nodes ModelExpress P2P
Models already on shared storage (NFS) PVC
Models in S3, GCS, Azure Blob Storage, or local safetensors paths ModelExpress + ModelStreamer
Frequent model updates across fleet ModelExpress P2P, optionally seeded by ModelStreamer
ModelExpress server with non-shared storage (RWO PVC, cross-namespace) ModelExpress with MODEL_EXPRESS_NO_SHARED_STORAGE=1

See Also