8 changes: 8 additions & 0 deletions HPXMLtoOpenStudio/resources/airflow.rb
Original file line number Diff line number Diff line change
Expand Up @@ -2325,6 +2325,14 @@ def self.apply_infiltration_adjustment_to_conditioned(runner, model, spaces, hpx
)
infil_flow.additionalProperties.setFeature('ObjectType', Constants::ObjectTypeInfiltration)

# Warmup workaround, see https://github.com/NatLabRockies/EnergyPlus/pull/11409
['Qducts', 'Qexhaust', 'Qsupply'].each do |var|
Model.add_ems_global_var(
model,
var_name: var
)
end

# Average in-unit CFMs (include recirculation from in unit CFMs for shared systems)
sup_cfm_tot = vent_fans[:mech_supply].map { |vent_mech| vent_mech.average_unit_flow_rate }.sum(0.0)
exh_cfm_tot = vent_fans[:mech_exhaust].map { |vent_mech| vent_mech.average_unit_flow_rate }.sum(0.0)
Expand Down
5 changes: 3 additions & 2 deletions HPXMLtoOpenStudio/resources/output.rb
Original file line number Diff line number Diff line change
Expand Up @@ -799,6 +799,8 @@ def self.apply_component_loads_ems_program(model, hpxml_osm_map, loads_data, sea
end
end

unit_multiplier = hpxml_bldg.building_construction.number_of_units

# EMS program: Internal Gains, Lighting, Infiltration, Natural Ventilation, Mechanical Ventilation, Ducts
{ 'intgains' => intgains_sensors,
'lighting' => lightings_sensors,
Expand All @@ -824,7 +826,7 @@ def self.apply_component_loads_ems_program(model, hpxml_osm_map, loads_data, sea
end
intgains_dhw_sensors.each do |sensor, vals|
off_loss, on_loss, rtf_sensor = vals
program.addLine("Set hr_intgains = hr_intgains + #{sensor.name} * (#{off_loss}*(1-#{rtf_sensor.name}) + #{on_loss}*#{rtf_sensor.name})") # Water heater tank losses to zone
program.addLine("Set hr_intgains = hr_intgains + (#{sensor.name} * (#{off_loss}*(1-#{rtf_sensor.name}) + #{on_loss}*#{rtf_sensor.name})) / #{unit_multiplier}") # Water heater tank losses to zone
end
if (not ducts_mix_loss_sensor.nil?) && (not ducts_mix_gain_sensor.nil?)
program.addLine("Set hr_ducts = hr_ducts + (#{ducts_mix_loss_sensor.name} - #{ducts_mix_gain_sensor.name})")
Expand Down Expand Up @@ -900,7 +902,6 @@ def self.apply_component_loads_ems_program(model, hpxml_osm_map, loads_data, sea
program.addLine(' EndIf')
program.addLine('EndIf')

unit_multiplier = hpxml_bldg.building_construction.number_of_units
[:htg, :clg].each do |mode|
if mode == :htg
sign = ''
Expand Down
16 changes: 8 additions & 8 deletions HPXMLtoOpenStudio/resources/waterheater.rb
Original file line number Diff line number Diff line change
Expand Up @@ -838,8 +838,8 @@ def self.apply_solar_thermal(model, spaces, hpxml_bldg, plantloop_map)
storage_tank.setHeaterThermalEfficiency(1)
storage_tank.ambientTemperatureSchedule.get.remove
apply_ambient_temperature(loc_space, loc_schedule, storage_tank)
storage_tank.setSkinLossFractiontoZone(1.0 / unit_multiplier) # Tank losses are multiplied by E+ zone multiplier, so need to compensate here
storage_tank.setOffCycleFlueLossFractiontoZone(1.0 / unit_multiplier)
storage_tank.setSkinLossFractiontoZone(1.0)
storage_tank.setOffCycleFlueLossFractiontoZone(1.0)
storage_tank.setUseSideEffectiveness(1)
storage_tank.setUseSideInletHeight(0)
storage_tank.setSourceSideOutletHeight(0)
Expand Down Expand Up @@ -1111,8 +1111,8 @@ def self.apply_hpwh_stratified_tank(model, water_heating_system, obj_name, solar
tank.setSourceSideFlowControlMode('')
tank.setSourceSideInletHeight(0)
tank.setSourceSideOutletHeight(0)
tank.setSkinLossFractiontoZone(1.0 / unit_multiplier) # Tank losses are multiplied by E+ zone multiplier, so need to compensate here
tank.setOffCycleFlueLossFractiontoZone(1.0 / unit_multiplier)
tank.setSkinLossFractiontoZone(1.0)
tank.setOffCycleFlueLossFractiontoZone(1.0)
apply_stratified_tank_losses(tank, tank_u, unit_multiplier)
tank.additionalProperties.setFeature('HPXML_ID', water_heating_system.id) # Used by reporting measure

Expand Down Expand Up @@ -1990,8 +1990,8 @@ def self.apply_water_heater(runner, model, name:, water_heating_system: nil, act
water_heater.setSourceSideFlowControlMode('')
water_heater.setSourceSideInletHeight((1.0 - (1 - 0.5) / 15) * h_tank) # in the 1st node of a 15-node tank (counting from top)
water_heater.setSourceSideOutletHeight((1.0 - (15 - 0.5) / 15) * h_tank) # in the 15th node of a 15-node tank (counting from top)
water_heater.setSkinLossFractiontoZone(1.0 / unit_multiplier) # Tank losses are multiplied by E+ zone multiplier, so need to compensate here
water_heater.setOffCycleFlueLossFractiontoZone(1.0 / unit_multiplier)
water_heater.setSkinLossFractiontoZone(1.0)
water_heater.setOffCycleFlueLossFractiontoZone(1.0)
apply_stratified_tank_losses(water_heater, tank_u, unit_multiplier)
else
water_heater = OpenStudio::Model::WaterHeaterMixed.new(model)
Expand Down Expand Up @@ -2028,8 +2028,8 @@ def self.apply_water_heater(runner, model, name:, water_heating_system: nil, act
skinlossfrac = 0.96 # Condensing
end
end
water_heater.setOffCycleLossFractiontoThermalZone(skinlossfrac / unit_multiplier) # Tank losses are multiplied by E+ zone multiplier, so need to compensate here
water_heater.setOnCycleLossFractiontoThermalZone(1.0 / unit_multiplier) # Tank losses are multiplied by E+ zone multiplier, so need to compensate here
water_heater.setOffCycleLossFractiontoThermalZone(skinlossfrac)
water_heater.setOnCycleLossFractiontoThermalZone(1.0)

water_heater.setOnCycleLossCoefficienttoAmbientTemperature(UnitConversions.convert(tank_ua, 'Btu/(hr*F)', 'W/K'))
water_heater.setOffCycleLossCoefficienttoAmbientTemperature(UnitConversions.convert(tank_ua, 'Btu/(hr*F)', 'W/K'))
Expand Down