Skip to content

himalunc/CreateJsonForL200DAQ

Repository files navigation

CreateJsonForL200DAQ

Create Json file for the DAQ machine at LNGS for L200 experiment Here is the corresponding data in detector google sheet for each column in ORCA configuration file. 1. For the Ge detector: Name in configuration → identification in ORCA → Name in detector sheet Detector 1. Serial → serial → 1st Column with no name 2. Type → det_type → 7 digit detector name starts with P, B and V are ppc, bage and icpc respectively String Layout 1. Str → str_number → String 2. Pos → str_position → Position FlashCAM DAQ 1. Crate → daq_crate → Flashcam (1st number is crate. eg: 1G5-2; 1 is crate #, G means Ge Det, 5 is slot number, and 2 is channel number) 2. Address → daq_board_id → check ORCA window to see which Flashcam is connected in which slot (check hardware at LNGS to be 100% sure) 3. Slot → daq_board_slot → Flashcam (2nd number is slot. eg: 1G5-2; 1 is crate #, G means Ge Det, 5 is slot number, and 2 is channel number) 4. Chan → daq_board_ch → Flashcam (3rd number after dash is channel. eg: 1G5-2; 1 is crate #, G means Ge Det, 5 is slot number, and 2 is channel number) High Voltage 1. Crate → hv_crate → HV crate is always 0 in L200 2. Slot → hv_board_slot → HV Module 3. Chan → hv_board_chan → HV Channel 4. Cable → hv_cable → kept blank in L200 (--) 5. Flange ID → hv_flange_id → HV Flange 6. Flange Pos → hv_flange_pos → HV Feedthrough (remove dots) Front-End Electronics 1. CC4 → fe_cc4_ch → use two input 'CC4'-'CC4-Channel 2. Analog → fe_head_card_ana → Flange 3. Digital → fe_head_card_dig → HE Addr 4. Fanout → fe_fanout_card → HE Cable 5. RPi → fe_raspberrypi → RPi 6. LMFE → fe_lmfe_id → LMFE

2. For SiPMS (LAr Detector) Name in configuration → identification in ORCA → Name in detector sheet Detector 1. Serial → serial → SiPM ID (with addition of 'S' in front of SiPM ID) 2. Type → det_type → Fiber ID (without number after -) FlashCam DAQ 1. Crate → daq_crate → Crate 2. Board ID → daq_board_id → check ORCA window to see which Flashcam is connected in which slot (check hardware at LNGS to be 100% sure) 3. Slot → daq_board_slot → Slot 4. Chan → daq_board_chan → Ch Low Voltage 1. LV Crate → lv_crate → not updated yet 2. LV Chan → lv_board_chan → not updated yet 3. LV Slot → lv_board_slot → not updated yet 4. Barrel Pos → lv_board_B_pos →use Angle to obtain this information 5. Loc → lv_board_string → need to obtain usinf information : 'if Fiber ID starts with IB or OB' and 'if later part of Fiber ID is divisible 2 or not' (1→ top outer barrel; 2→ top inner barrel 3→ bottom inner barrel, 4→ bottom outer barrel)

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published