forked from kytos/mef_eline
-
Notifications
You must be signed in to change notification settings - Fork 9
Issues: kytos-ng/mef_eline
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Author
Label
Projects
Milestones
Assignee
Sort
Issues list
docs/research: assessment to support PHP just so inter-EVC on telemetry_int can also leverage it
#628
opened Feb 18, 2025 by
viniarck
handle_link_down got stuck due to one EVC lock never acquired
bug
Something isn't working
priority_critical
Critical priority
#623
opened Feb 11, 2025 by
italovalcy
Disabling an Interface and releasing the VLAN can lead to duplicated EVCs
#619
opened Feb 6, 2025 by
italovalcy
Change an UNI to a disabled interface may result on never releasing the VLAN
2024.2
Kytos-ng 2024.2
bug
Something isn't working
#618
opened Feb 6, 2025 by
italovalcy
tech_debt: replace pathfinder request with a Tech debt
pathfinder
manager func call
epic_napp_to_napp_calls
tech_debt
#615
opened Jan 31, 2025 by
viniarck
Backport PR #583 to consistency
priority_major
Major priority
2023.2
backport_20232
epic_mef_eline_consistency_v2
#600
opened Jan 6, 2025 by
Ktmi
Standardized returns for remover/installer methods that involve Flows
#582
opened Dec 3, 2024 by
Alopalao
bug: Something isn't working
future_release
Planned for the next release
maintenance
on a UNI interface will keep the EVC status as active
bug
#576
opened Nov 27, 2024 by
viniarck
Link down affecting current_path and failover_path can result in inconsistencies
2024.2
Kytos-ng 2024.2
backport_20232
backport_20241
bug
Something isn't working
priority_critical
Critical priority
#575
opened Nov 26, 2024 by
italovalcy
Possible EVC duplication for UNIs with no TAGs
bug
Something isn't working
future_release
Planned for the next release
#569
opened Nov 15, 2024 by
Alopalao
bug: request failure during deployment switch mid iteration still left the EVC active; it didn't rollback
bug
Something isn't working
epic_mef_eline_flows_error_handling
priority_low
Low priority
#555
opened Oct 31, 2024 by
viniarck
bug/usability UX: Something isn't working
tech_debt
Tech debt
Link
s status
and status_reason
of a Path
aren't always coherent
bug
#554
opened Oct 30, 2024 by
viniarck
feature: having different vlan pool allocations for UNIs and NNIs
backport_20232
backport_20241
enhancement
New feature or request
priority_critical
Critical priority
#545
opened Oct 23, 2024 by
viniarck
Possible incorrect trace and inconsistent EVC
2025.1
Kytos-ng 2025.1
future_release
Planned for the next release
#538
opened Oct 21, 2024 by
italovalcy
Backport 2023.2 - PR 528 - fix default collapsed path constraint options on EVC creation
#530
opened Oct 7, 2024 by
italovalcy
Double check event listener for interface link change -- seems too broad
#523
opened Oct 5, 2024 by
italovalcy
Link maintenance should reflect on the service being deactivated if no alternative path is found
#519
opened Oct 2, 2024 by
italovalcy
EVCs modified without holding lock, may lead to race conditions
2024.2
Kytos-ng 2024.2
epic_mef_eline_consistency_v2
consistency
#512
opened Sep 23, 2024 by
Ktmi
Add error status to detect when an EVC had problems
2025.1
Kytos-ng 2025.1
epic_mef_eline_flows_error_handling
#511
opened Sep 19, 2024 by
Alopalao
Previous Next
ProTip!
What’s not been updated in a month: updated:<2025-02-13.