Programming opentrons robot

This script automates a portion of the new opentrons pipetting robot using the opentrons api (OT-2 API V2). More specifically, it automates the dilution step (concentration normalisation) after PCR amplification and a picogreen assay in the arctic protocol on all samples above the threshold concentration. It then performs the end-repair and barcoding on all normalized samples. Samples are then consolidated into a single tube.

Input data

This protocol accepts raw DNA concentration data from the Optima plate reader in .xlsx format. The most recent .xlsx file will be read in from /path/on/robot/ to serve as an entry point to the script. Upload an .xlsx file relating to the samples to run the script.

Info

  • Save plate reader output as a .xlsx file in /path/on/robot/
  • The samples will need to be laid out as described in the SARS_SOP.
  • Up to 24 samples per run.
  • Samples with a concentration < 4ng/ul will be skipped.
  • The position of the sample on the plate will determine which barcode is used.
  • Columns 1,2 and 3 can contain sample data. Column 4 must contain Pico standards data.

Example of a plate layout of 21 samples and Pico green standards, with optima data in cells:

Sample Sample Sample Pico
1 2 3 4 5 6 7 8 9 10 11 12
A 677 28594 3233 121
B 26822 27726 43193 43244
C 41125 1523 19965 5330
D 7455 42273 2204 709
E 38978 43020 312 186
F 3312 6831
G 1476 44124
H 1650 2212

Simulate protocol

Create and activate a conda environment to get the minimum python version required for a non-jupyter opentrons installation

conda env create -f opentrons_env.yml
conda activate opentrons_env

Simulate the protocol from the command line

opentrons_simulate normalisation.py

Deck lay out

This protocol requires:

  • Tips:

    1. Opentrons 96 filtertips 20ul; Slots 8 and 9
    2. Opentrons 96 filtertips 300ul; Slot 6
  • Temperature Module: Slot 10

  • 12 well reservoir 22ml: Slot 11

  • 24 tube rack for enzymes: Slots 4 and 7

  • End repair kit

  • Ligation kit

  • Barcodes

Barcodes rack layout

Barcodes are in held in a 24 tube rack in slot 4. The tubes should be laid out as shown below.

1 2 3 4 5 6
A NB01 NB02 NB03 NB04 NB05 NB06
B NB07 NB08 NB09 NB10 NB11 NB12
C NB13 NB14 NB15 NB16 NB17 NB18
D NB19 NB20 NB21 NB22 NB23 NB24

Enzyme rack layout

1 2 3 4 5 6
A End repair Buffer 5x End repair Enzyme Empty Tube Ligation Master Mix Ligation Enhancer Empty Tube
B
C
D Empty Tube

Empty tubes are for making master-mixes and collection of the final samples. It is very important these are included or you will lose all the samples and waste the reagents.